INS-AX2 series simulators are the advanced version of the conventional manually operated INS-4020/4040 simulators, maintaining the identical interference signal characteristics while offering a new level of ease of use.
Key Features
• An innovative, motor driven coaxial switch mechanism eliminates the need to manually plug and unplug coaxial connectors, allowing a preset test sequence to be carried out seamlessly including pulse width and coupling mode changes, automatic voltage ramp and others.
• As well as manual control, the simulator can be remote-controlled through a fiber optic computer interface. A Windows control software package is supplied as an included accessory.
• Floating output
• 8 pulse widths installed: 10ns, 50ns, 100ns, 200ns, 400ns, 500ns, 800ns and 1000ns
• Internal switchable terminators
• Easily changeable and safety-interlocked outlet panel (EUT interface)
• 3 channels EUT fail input
• Remote Control Software (Included accessory)
: Complete, comprehensive ready-made Windows software to control the INS-AX2 simulator remotely from your PC
Spec Comparison
Item | Model | ||
INS-AX2-220/250 | INS-AX2-420/450 | ||
Pulse output voltage | 0.01 ~ 2.00kV±10% at 0.01kV step | 0.01 ~ 4.00kV±10% at 0.01kV step | |
±0.04kV allowance for <0.1kV setting | |||
Output polarity | Positive or negative | ||
Pulse | Pulse width | 50, 100, 200, 400, 500, 800, 1000ns ±10%, 10ns±3ns | |
Rise time | <1ns | ||
Output impedance | 50 ohm system (53.5 ohm) | ||
Pulse repetition mode | Variable | 10ms ~ 999ms±10% | 16ms ~ 999ms±10% |
Phase | Injection phase angle 0 to 360 degrees±10 degrees | ||
1 shot | Single pulse generation, each time the 1 SHOT button is pressed. | ||
Power capacity of EUT | INS-AX2-220: | NS-AX2-420: | |
Power supply | AC 100V~240V±10%, 50/60Hz±10% | ||
Power consumption | 110VA | ||
Operating temperature and humidity range | 15 ~ 35°C, 25 ~ 75% (No dewing shall occur.) | ||
Dimensions | W 430 x H 350 x D 470mm, projection excluded | ||
Weight | INS-AX2-220: Approx. 30Kg | INS-AX2-420: Approx. 30Kg | |
Mercury relay unit | Model: 04-00014A | Model: 04-00015A |
TRIANGULAR PULSE ADDITION (Factory Option)
Parameters | Specifications | |
Output pulse waveform | Triangular pulse | |
Pulse output voltage | 2kV (220/250) and 4kV (420/450) max (when the output is terminated by the internal resistors) | |
Output polarity | Positive or negative | |
Pulse | Duration | 1μs±30% |
Rise time | <40 ns |
Ordering Information
Contents
• INS-AX2-420 Impulse Noise Simulator
• Outlet panel (18-00067A, Single phase terminal block type)
: AC 240V, DV 65V, 20A max
• Power cable
• Remote control software (14-00033A, CD-ROM)
• Optic-RS232C converter (07-00017A)
• Optical cable (5m)
• D-sub conversion connector
• Instruction manual
: for the simulator and remote control software
※ 자세한 사항은 데이터시트나 매뉴얼을 참조해 주십시오.
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?