Accessoires Included
◆ 사용 설명서◆ 건전지◆ 휴대용케이스 (93031/93033)
Additional Information
Weight | 120 / 270 / 570 g |
---|---|
Dimensions | <CL320> 60 (W) x 149 (H) x 26 (D)mm <CL340/CL345> 81 (W) x 185 (H) x 40 (D) mm <CL360>129 (W) x 248 (H) x 55 (D) mm |
Product Specifications
<CL320> Description | Leakage Current Mini Clamp-on |
---|---|
Method of detection | Mean Value |
Display | LCD (Digital display: 1999 counts) |
Response Time | Approx. 2 seconds |
Range Switching | Manual-range |
Data hold | On all range |
Operating temperature and humidity | 0 - 40°C, 85% RH or less (no condensation) |
Influence of external magnetic field | 10 mA or less in proximity to a 14.4 mm-dia conductor carrying 100A |
Influence of conductor position | Within 5 dgt for 0 to 50A, or 2% for 50 to 200A (10 mm-dia conductor at inside the jaw) |
Influence of Residual Current | 10 mA or less in proximity to a 10 mm-dia conductor carrying 50A |
Safety Standard | Conforms EN61010-1, EN61010-2-032 |
Circuit voltage | 300 Vrms or less |
Withstanding voltage | 3.7 kV AC for one minute |
Power Supply | LR-44 x 2(3V) |
Battery Life | Approx. 15 hours (continuous) |
Consumed current | Approx. 5 mA |
Auto power-off | Approx. 10 minutes |
Diameter of measurable conductor | 24 mm at maximum |
<CL340> Description | Leakage Current Mini Clamp-on |
---|---|
Method of detection | Mean Value |
Display | LCD (Digital display: 3999 counts) |
Response Time | Approx. 2 seconds |
Range Switching | Manual-range |
Data hold | On all range |
Operating temperature and humidity | 0 - 40°C, 85% RH or less (no condensation) |
Influence of external magnetic field | 10 mA or less in proximity to a 15 mm-dia conductor carrying 100A |
Influence of conductor position | 40/400 mA range: Within 5 dgt at every part inside the jaw400A range, 0 to 250A:Within ±0.5% rdg ±5 dgt at every part inside the jaw section |
Influence of Residual Current | 12 mA or less in proximity to a 10 mm-dia conductor carrying 100A |
Safety Standard | Conforms EN61010-1, EN61010-2-032 |
Circuit voltage | 300 Vrms or less |
Withstanding voltage | 3.7 kV AC for one minute |
Power Supply | LR03 x 2 R0-3(UM-4) x 2 |
Battery Life | Approx. 40 hours (continuous) |
Consumed current | Approx. 13 mA |
Auto power-off | Approx. 10 minutes |
Diameter of measurable conductor | 40 mm at maximum |
<CL345> Description | AC LEAKAGE |
---|---|
Method of detection | True RMS |
Display | LCD (Digital display: 4200 counts) |
Response Time | Approx. 2 second |
Range Switching | Manual-range |
Data hold | On all range |
Operating temperature and humidity | 0 - 40°C, 85% RH or less (no condensation) |
Influence of external magnetic field | 10 mA or less in proximity to a 15 mm-dia conductor carrying 100A |
Influence of conductor position | 40/400 mA range: Within 5 dgt at every part inside the jaw 400A range, 0 to 250A: Within ±0.5% rdg ±5 dgt at every part inside the jaw section |
Influence of Residual Current | 12 mA or less in proximity to a 10 mm-dia conductor carrying 100A |
Safety Standard | Conforms EN61010-1, EN61010-2-032 |
Circuit voltage | 300 Vrms or less |
Withstanding voltage | 3.7 kV AC for one minute |
Power Supply | LR03 x 2 |
Battery Life | Approx. 24 hours (continuous) |
Consumed current | Approx. 21 mA |
Auto power-off | Approx. 10 minutes |
Diameter of measurable conductor | 40 mm at maximum |
<CL360> Description | Leakage current clamp on AC 1000A |
---|---|
Method of detection | Mean Value |
Display | LCD (Digital display: 1999 counts) |
Response Time | Approx. 1 second |
Range Switching | Manual-range |
Data hold | On all range |
Operating temperature and humidity | -10 - 50°C , 80% RH or less (no condensation) |
Influence of external magnetic field | 15 mA or less in proximity to a 10 mm-dia conductor carrying 100A |
Influence of conductor position | 2% or less |
Influence of Residual Current | 10 mA or less in proximity to a 10 mm-dia conductor carrying 100A |
Safety Standard | Conforms EN61010-1, EN61010-2-032 |
Circuit voltage | 300 Vrms or less |
Withstanding voltage | 3.7 kV AC for one minute |
Power Supply | 6 LR61 x 1 6F22 (006P) 9V x 1 |
Battery Life | Approx. 60 hours (continuous) |
Consumed current | Approx. 5 mA |
Diameter of measurable conductor | 68 mm at maximum |
Key Features
◆ 누설 전류 측정은 전류 범위가 20mA ~ 200A / 40mA ~ 400A / 200mA ~ 1000A
◆ 가볍고 컴팩트한 디자인
◆ 수동 범위 전환 및 자동 전원 끄기 기능
◆ 측정 가능한 도체의 직경 24/40/68mm
◆ 평균값표시
◆ 자동 전원 끄기
◆ 수동범위전환
◆ 안전 표준 EN610-1, EN610-2-032(CAT. III 300 V) 준수 승인
Accessoires Included
Additional Information
Weight | 120 / 270 / 570 g |
---|---|
Dimensions | <CL320> 60 (W) x 149 (H) x 26 (D)mm <CL340/CL345> 81 (W) x 185 (H) x 40 (D) mm <CL360>129 (W) x 248 (H) x 55 (D) mm |
※ 자세한 사항은 'DataSheet'나 'Quick Start Guide'를 참조해 주세요.
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?